Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDRURY INN AND SUITES
Address6920 NORTHLAKE MALL DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/15/2025
Final Score @ Grade
18
General CommentsCPO Rodney Searcy not present for today’s inspection. Went over inspection with manager Katherine Conrad. Pool permitted for night swimming. Not able to verify that outdoor lighting works. Will check on a future visit. No label observed on pool pump. Verified Pentair Challenger pump with 2 HP motor. Electrical whip to pool motor not fully installed, wiring exposed. Ensure wiring is properly installed by a licensed electrician. Intent to suspend issued 8) 12) 17)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one of two weirs. Other weir not functioning. .2518(k) Provide functional weirs. - Intent to suspend item. Both skimmers full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No All ladders loose. .2521 Install ladders per manufacturer instructions. One handrail loose. .2521 Install handrails per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Table and chairs too close to handrail. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some items stored directly beside or on top of equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemical storage room very cluttered. Lots of chemicals stored on top of each other. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.