| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item. |
|
4
|
6
|
Water quality: water temperature of heated pool |
No |
No
|
No |
Temperature 90.8F. .2535(12) Maintain pool temperature at 90 F or below. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No Main Drain checks observed. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for and total alkalinity. - Intent to suspend item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Aquastar 6 HP drain covers installed with 2 screws, rather than 4 screws as per manufacturer's instructions. One of the screws is loose. .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. - Immediate suspension item.
New 2HP motor installed on unlabeled Pentair Challenger Pump. Provide pump documentation (invoice, photo of impellor serial number, or equivalent) and updated PDSC form if pump is different than the pump we have on file. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with leaves and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders loose. Some ladders missing endcaps. .2521 Install ladders per manufacturer instructions. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs too close to the pool deck. .2522(a) Provide 6 ft of clear walking space around the outdoor portion of the pool. .2522(b) Provide at least 5 ft of clear walking space around the indoor portion of the pool. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some items stored beside pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Some chemicals in the pump room. Observed loose bromine briquets on the floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some pipe labeling worn off. .2518(d) Piping and valves shall be labeled with color codes or labels. |