| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Bromine at 0.4 ppm. Maintain at least 2ppm free bromine. Operator added pucks, was able to adjust to 1ppm after at least an hour of waiting. - Immediate suspension item., |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Green algae growing in corners and ladders. Maintain proper water chemistry and maintain pool algae free. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Both weirs missing. Install functional weirs. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Most ladders loose and missing endcaps. Maintain ladders secure and in good condition. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Missing a few inlet fittings. Install functional inlet fittings. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
One ring buoy with throw rope too short. Provide 33 foot throw rope for ring buoy. Removed from deck by operator. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
One chair too close to pool. Maintain at least 5 feet clear walkway on indoor part and 6 feet clear walkway on outdoor part of pool deck. Corrected by operator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leaks in pump room. Fix leaks.
Fan not working for chemical storage room. Provide proper ventilation.
Light in chemical storage room not working. Provide proper lighting. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Main drain piping not labeled. Ensure all pipes are labeled. |