3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0. Maintain between 7.2 and 7.8. Corrected to 7.4. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Recently used pool logs do not have a place for main drain checks. Check daily main drains. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Waterway 640-470 covers recalled. Either replace with A112 approved covers or install retrofit kit to make covers A112 approved. - Immediate suspension item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Some ladders loose. Maintain secure and in good condition. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some deck chairs too close to edge of pool. Maintain at least 6 feet clear walkway around pool in outside section, and at least 5 feet clear walkway around inside section. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Maintain at least 3 feet clear walking space around pool equipment in pump room. |