Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameESTATES AT BALLANTYNE, THE
Address16311 HAWFIELD WAY DR
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/19/2026
Final Score @ Grade
12
General CommentsConducted inspection with operators. Pool in compliance and returned to A status. EHS recommends lowering chlorine for bather comfort. Pool pump motor replaced. Pool not heated. No night Swimming. PERMIT RESTRICTION: PENTAIR 011056 MUST BE RUN AT 3450 RPM DUE TO TURNOVER AND DESIGN APPROVAL

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope 1 ft too short. Operator replaced rope. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Operator filled hole and corrected. Front gate piece to close gap greater than 1/2” within 18” of latching mechanism loose. Operator re secured. Fence built prior to 2010. Back gate welded shut and no longer accessible. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Some chemicals in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Overhead ventilation not operational. Repair.