Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameESTATES AT BALLANTYNE, THE
Address16311 HAWFIELD WAY DR
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/14/2025
Final Score @ Grade
18
General CommentsPool not heated. No night Swimming. CPO updated to Travis Feazell PERMIT RESTRICTION: PENTAIR 011056 MUST BE RUN AT 3450 RPM DUE TO TURNOVER AND DESIGN APPROVAL

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed records missing weekly cyanuric acid and total alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No At time of inspection, 1 weir missing, multiple weirs observed installed upside down. Skimmers observed with debris. .2518(k) Replace missing weirs. Install per manufacturer, correctly. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator replaced missing weirs, corrected others to be installed correctly and emptied baskets. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate missing piece to close gap greater than 1/2” within 18” of latching mechanism. Observed fence to not be to the current specifications. Fence built prior to 2010. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Operator filled hole and corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and pool furniture within 6' of pool at time of visit. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved items and corrected.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Showers off at time of inspection. .2526(h) Shower(s) shall be provided.