Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameESTATES AT BALLANTYNE, THE
Address16311 HAWFIELD WAY DR
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/26/2022
Final Score @ Grade
24
General Comments30 Day Intent to Suspend (ITS) for records, gates self-close, self-latching, gaps greater than 1/2” within 18” of latching mechanism and inlet fitting. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Changed to “W” status Inspection with Augusta Washington CPO UPDATED TO DOUGLAS HICKMAN If Pool plastering is done submit infield plan review application to avoid permit action with LRV.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed records missing, main drain checks and weekly cyanuric acid and total alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed body hook on ground. .2530(a) Lifesaving equipment should be conveniently located. operator moved and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not closing or latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching.*permit item Fence decorative cut outs/horizontals less than 45" in height. Pool built '08. .2528(b) Horizontals shall not be located less than 45" in height. Small squares over 1", cut out for locking cable through gate, greater than 1/2", within 18" of latching mechanism. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of release mechanism. *permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and pool furniture within 6' of pool at time of visit. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Inlet fitting missing .2518(i) Arrange inlets to produce uniform circulation. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Standing water on floor of pump room. No 3 foot clearance around equipment. Light out in chemical room. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(6) Provide sufficient lighting in chemical storage room.