Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameESTATES AT BALLANTYNE, THE
Address16311 HAWFIELD WAY DR
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/12/2022
Final Score @ Grade
28
General CommentsIssued local permit sticker. No Night Swimming. 1. Permit Restriction – Pentair 011056 must be run at 3450 RPM due to turnover and design flow approval. 2. Filtration Pumps verified – Pentair 011012 and new pump 011056 installed. 3. All piping 4” – md, sk, return 4. EQ lines plugged in skimmer/plugged in wall 5. (2) Pentair TR140c filters 6. Number of returns: 13 open returns 7. 5 skimmers 8. Two feature pumps tied together (2) Intelliflo VS3050 011013 9. Two main drains Aquastar 1216 CPO updated Niko Agnew

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some skimmers with debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One inlet fitting missing (out of 13) .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Lack of severity does not warrant permit action at this time. Replace fitting prior to next inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not closing or latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching.Operator corrected to self-close, self-latch. Fence decorative cut outs less than 45" in height. Fence less than 48" in some areas. Pool built '08. .2528(b) Horizontals shall not be located less than 45" in height. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Small squares over 1", cut out for locking cable through gate, greater than 1/2", within 18" of latching mechanism. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of release mechanism. Operator filled and corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck cracked with offset greater than 1/2" at time of inspection. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Operator filled crack and corrected.
18 4 Premises: lifeguards present or warning signs posted No No No Signage missing "the" for rule: .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Operator printed new signage and posted. Advised ordering new sign.
22 6 Premises: emergency telephone provided No No No Emergency phone signage observed with incorrect callback number. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator updated to correct number. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light and ventilation out in chemical storage room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(6) Provide sufficient lighting in chemical storage room.