Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameESTATES AT BALLANTYNE, THE
Address16311 HAWFIELD WAY DR
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/13/2021
Final Score @ Grade
22
General CommentsEmergency phone clarity on line must be corrected by 4/20/21. Failure to correct will result in Immediate Suspension. Contact Marie Daley at 704-507-6806 when in compliance. ITS for gates and records. Changed to "W" status. Pool not heated. No Night Swimming. Send Night Swimming verification to Marie Daley or schedule visit before dawn/after dusk to verify sufficient lighting. Inspection with Alex Garcia No signature due to COVID

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing main drain checks and maintenance for water when chemicals recorded out of range. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. **Permit item. Will be verified at return visit for verification.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not closing or latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching.**Permit item. Contact Marie Daley when in compliance to lift ITS. Must correct by 4/30/2021 (permit expiration) for new permit. Fence decorative cut outs less than 45" in height. Fence less than 48" in some areas. Pool built '08. .2528(b) Horizontals shall not be located less than 45" in height. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and pool furniture within 6' of pool at time of visit. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone dialing out, but operator having trouble hearing, cutting in and out. .2530(f) Emergency phone shall remain operable. **Allowed 7 days from inspection, until 4/20/2021, to address since phone is working. Failure to correct by 4/20/21 will result in Immediate Suspension of permit.** Contact Marie Daley at 704-507-6806 when in compliance to verify.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in equipment room. Salt and other storage in designated chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Items and chemicals within 3' of equipment and piping. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. No backflow prevention on hose bib outside of pump room. Pool built '08. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels for hand drying in men's restroom at time of inspection. Provide hand drying. .2526(m) Keep restrooms and fixtures clean and in good repair. Operator replaced and corrected.