Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSOUTHMINSTER
Address8919 PARK RD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/4/2023
Final Score @ Grade
14
General CommentsInspection conducted with operator Troy. 30 day intent to suspend the permit issued for door not self closing and latching. Once door is repaired call Hope McIntosh at 980-229-7549 for a re-visit. If not corrected within 30 days, permit may be suspended. Note: emergency phone is operable, however, line has a lot of static and is not clear. Charlotte 911 verified at this time they would be able to communicate, however, phone line should be evaluated.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool water pH greater than 7.8. Corrected to 7.6.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Exit door to right of pool not fully self closing.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed pool chemicals not stored in designated chemical storage room - instead stored in “storage room” off of pool deck which is not ventilated.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Observed water at locker room shower heads exceeding 110f.