2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
0.4 ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
Test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One out of 2 weirs missing at time of inspection. .2518(k) Replace missing weirs. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
One ring bouy damaged. Outer rope snapped. .2530(a) Provide USCG approved ring buoy. - Corrected. Operator removed damaged ring bouy, second bouy in good shape. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One door to patio not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Some pool piping is PVC-DWV piping. .2518(d) Plastic pipe shall be a minimum of schedule 40 PVC. - Will follow up with facility.
Flow meter stuck. Pool has a permit condition that flow meter must be operational at 60 GPM or less. .2518(g) Install flow meter on return line per manufacturer instructions and keep operational such that it reads within +/- 10% accuracy. - Immediate suspension item.
Tab on vacuum cap lid allowing it to be opened without the use of a tool. .2518(f) Provide a vacuum cap or self-closing cap designed to be opened with a tool for pools built after May 1, 2010. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed standing water on pump room floor. .2533(d) Pump room floor shall be kept dry and free of standing water.
Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Inadequate ventilation in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms over 132.6 F. .2526(i) Water in restrooms shall not exceed 110 F. |