3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 7.0 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8. Operator added chemicals and corrected to 7.2. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One out of 2 weirs missing at time of inspection.
.2518(k) Replace missing weirs. Operator replaced and corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Tiling by side of pool and by entry railing offset greater than 1/2”. .2537(2) Decks shall be kept in good repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed standing water on pump room floor. Some items within 3’ of equipment. .2533(d) Pump room floor shall be kept dry and free of standing water.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms over 110 F. .2526(i) Water in restrooms shall not exceed 110 F. |