2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed chlorine level of 0.5 ppm at time of inspection. .2535(5) Maintain chlorine at least 1.0 ppm. IMMEDIATE SUSPENSION ITEM. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records not being kept at time of inspection.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.
*permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Debris in skimmers at time of visit. One weir stuck.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and adjusted weir. Corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope tangled at time of inspection.
.2530(a) Lifesaving equipment should be conveniently located. Operator untangled and corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door into pool stays open when opened all the way. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*Permit item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs within 5' of pool.
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Operator moved and corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Placed on immediate hold from front desk when emergency phone called back.
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
Manager educating staff on answering and monitoring emergency calls. Corrected through education. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed standing water on pump room floor. Some items within 3ā of equipment. .2533(d) Pump room floor shall be kept dry and free of standing water.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms over 110 F. .2526(i) Water in restrooms shall not exceed 110 F. |