Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON GARDEN INN AYRSLEY
Address1920 AYRSLEY TOWN BLVD
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/7/2021
Final Score @ Grade
28
General CommentsIMMEDIATE SUSPENSION ITEMS: - Disinfectant residual- bromine level must be min. 2ppm ITEMS THAT MAY WARRANT AN INTENT TO SUSPEND PERMIT: - Weirs must be present at all skimmers - Cover/plug for vacuum port **Please ensure pool records are accurately kept, with pH, bromine, temperature, and main drain daily. Total akylinity checked weekly. Stacie Rhea present at time of inspection. Please contact EHS when ready to have suspension lifted, (704)-371-1589.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(5) Maintain bromine at least 2.0 ppm. Observed bromine level of 0.0ppm at time of inspection. IMMEDIATE SUSPENSION ITEM.
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH level of 8.4 at time of inspection. CDI: CPO corrected pH level. Pool now reads 7.7.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed walls at water line stained with gray film.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Surface skimmers shall be installed per manufacturer's instructions. Observed weir on deep end of pool not attached securely. MAY WARRANT INTENT TO SUSPEND.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed cover for vacuum port with no cover and beginning to separate from wall. MAY WARRANT INTENT TO SUSPEND.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water on pump room floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Observed hot water in men's restroom at 129F and women's restroom at 114F.