NameHILTON GARDEN INN AYRSLEY
Address1920 AYRSLEY TOWN BLVD
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/28/2015
Final Score @ Grade
26
General Comments#15 Throw rope on ring buoy shortened to ~18' by the way it is tied (21' required). ** CDI #25 Equipment and chemical room do not have natural cross draft ventilation. ** Determine if a forced air vent fan is present to exhaust air to exterior of building.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Pool water temperature being recorded every 5-6 days. ** Record daily.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Garbage (plastic cups, etc.) below skimmer baskets. ** Corrected during inspection. (CDI)
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Large tile not secured to pool deck near ladder. ** Correct. Chair ~2.5" and table ~3.5' from pool edge. ** Maintain 5' of clear walking space.
22 6 Premises: emergency telephone provided No No No Phone automatically dials 911 when handset is lifted. Incorrect dialing instructions posted at phone. ** CDI Leak in piping @ pool water heater. ** Per CPO, already has parts to fix.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter float stuck. ** Correct.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemical room does not have a light. ** Room should have a light fixture. Chlorine & muriatic acid drums stored in equipment room. ** Chemical room too small to accomodate.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water 135.2F at lavatories in restrooms. ** Turn water temperature down. Maximum allowed is 110F.