Inspection Date 11/26/2014
Final Score @ Grade
24
General Comments#15 Observed 2nd buoy with unattached 16' throw rope. **2nd buoy not required; however, if it is on pool deck, the throw rope must be 21' & attached/ tied to ring buoy. The 2nd ring bouy was removed from pool deck while EHS on-site. GC #25 Equipment room floor is wet @ spa circulation system. **Find source of leak & resolve to keep equipment room dry. Observed that chemical room/ closet does not have a light. **Room should have light fixture. Immediate suspension issued for #3. Pool cannot re-open until written approval is obtained from the Meck. Co. Health Dept.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH @ 6.8. **Maintain pH 7.2. to 7.8 Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No written records of water quality availabe to review. **Maintain pool records at pool for daily & weekly entries and for review. EHS gave MCHD pool record form for immediate use.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed that both weirs are missing. **install. Observed disposable cups & clumps of hair in skimmer baskets. **clean.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed broken & raised deck tiles at ladder. Observed broken tile (deck) near ladder. **replace/ resolve. Observed table & chair ~2'-3' from pool edge. **Maintain at least 5' of clear walking space.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed that flow meter float is stuck. **resolve.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water 136.9F @ lavatories in restroom off pool/ spa deck. **Lower hot water temperature - Maximum temperatue allowed is 110F.