3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. Corrected to 7.2. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
Cyanuric acid well above 100 ppm. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. - Intent to suspend item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One of two weirs missing. .2518(k) Replace missing weirs. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder missing endcap. .2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook not attached to the pole. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chair too close to pool. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals and non-chemical items stacked on top of each other, not able to see the floor or easily access items. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |
|