3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH > 8.4. Maintain between 7.2. and 7.8. Operator added muratic acid to lower pH. Must keep pool closed for at least one water turnover and corrected pH verified by inspector. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records kept since 5/15. Operator switched to a new sheet with no place for main drain checks. Check daily Cl, pH, temperature, main drains and at least weekly Total Alkalinity and Cynuric Acid. Cyanuric acid at 90ppm on pool log sheet. Maintain cyanuric acid at no more than 100 ppm. - Intent to suspend item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
New Custom Molded Products Galaxy 25507-100 main drain covers installed. Provide updated PDSC form to reflect this change. Corrected PDSC form filled out and approved. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
One ring buoy damaged. Removed by operator. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Incorrect dialing instructions posted at emergency phone. Phone automatically dials 911 when handset is lifted. Provide signage at emergency phone with accurate dialing instructions, emergency phone number, and address. - Immediate suspension item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Fixed by operator. |