8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets full. Ensure skimmer baskets emptied regularly to ensure filtration working per requirement. Emptied during the inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Step handrail loose. Tighten. Keep in good repair. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope for ring buoy tangled and 1 ft. short. Required at 31 ft. Untangled and lengthened during the site visit to 31 ft.
Rusted screws on body hook/pole. Replace screws to ensure body hook secured to pole. Repair prior to return visit for the phone. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Barrier wall less than 45" from top of fencing/gates. Maintain 45" between horizontals. Provides a foothold. Pool built pre-2010.
Lights provide footholds next to barrier.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
One light burnt out in pool. Repair light for night swimming approval.
Night swimming approval due by end of 2026. Follow-up site visit will be required to renew night swimming approval. Schedule once light repaired. Will give 30 days for light repair once permit is reinstated. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone not operable. Phone connecting to 911; however, speaker not operable and 911 could not be heard. 911/EHS shall be clearly audible. Address and phone number shall transfer to 911. Could not verify address or phone number. Phone shall audibly
ring or answer automatically when number is dialed. Immediate Suspension issued. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Flow meter on chlorinator clouded with chlorine. Not operable. Flow meter shall be operable per NSF requirement. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Tablets stored in pump room. Moved during the inspection. Ensure all dry chemicals are stored in the chemical storage room. |