| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 8.0. Corrected during the inspection to 7.6. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Last three days CPO not present at the property. No records maintained. CPO shall visit property at least daily. Maintain daily record keeping for chlorine, pH and main drain checks. CPO is required on all days the pool is open to the public. If not present, the pool shall close. Spoke with CPO - no CPO on weekends present after questioned. Provide "plan" for CPO on weekends. Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers full of debris. Emptied during the inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Barrier wall less than 45" from top of fencing/gates. Maintain 45" between horizontals. Provides a foothold. Pool built pre-2010. Lights provide footholds next to barrier.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Back gate blocked by pool furniture. Move pool furniture so that gate is accessible. Intent to Suspend issued.
Pool furniture <6 ft. to pool especially at steps and around entire pool area. Areas with enough space for emergency response. No permit action taken at this time. Move furniture to ensure 6 ft. clearance. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Operator repaired during the inspection. Flow required at 84 gpm to 120 gpm to meet turnover and flow restriction of the drain covers. Flow meter installed does not meet mfg. specifications. Will require a 5% accurate flow meter prior to 2026 season due to drain cover flow restriction. Suction Hazard. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash pit not capable of holding water flow with backwash. Overflowing. Backwash pit shall be capable of handling flow. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
One soap dispenser in men's not operable. Repair soap dispenser. |
|