7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some leaves/debris on pool floor. Operator cleaned pool during the inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
End cap missing off of ladder. Replaced during the inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Barrier wall less than 45" from top of fencing/gates. Maintain 45" between horizontals. Provides a foothold. Pool built pre-2010. Lights provide footholds next to barrier.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pooling water across from shower area. Some build-up but does not appear slick. In walkway to pool. Monitor and clean as needed.
Pool furniture within 4 ft. of pool edge. Maintain 5 ft. clearance. Repeat non-compliance. One chair blocking entry walkway. Moved during the inspection. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Address sign blocked by phone emergency sign. Corrected during the inspection. Phone number faded off of pool phone. Corrected during the inspection. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not reading permit restriction at 84 to 120 gpm. Backwashed during the inspection. Reading 93 gpm at final. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Tablets kept in pump room. Store all chemicals in chemical storage room. |