16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Barrier wall less than 45" from top of fencing/gates. Maintain 45" between horizontals. Provides a foothold. Pool built pre-2010.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
Private barrier gate sticking on grass. Corrected to self-close, self-latch during the inspection. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool furniture less than 6 ft. to pool edge. Maintain 6 ft. clearance around pool in all locations.
Some damage to deck drain. Outside of required deck space. Located in area near walkway to private patio.
Note: Pool coping replaced and decking repaired to eliminate offsets and trip hazards. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone not operational. Phone number faded off phone. Could not verify phone number and address with 911. Phone shall connect to 911 and be capable of callback. Immediate Suspension issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
No spare pump basket for pump. Provide spare pump basket. Intent to Suspend item.
Flow meter installed is new. Not capable of 1.5xdesign flow of pump. Flow meter shall be capable of reading up to at least 156 gpm. Intent to Suspend item. |