NameAVENUE
Address210 N CHURCH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/20/2021
Final Score @ Grade
26
General Comments6 - New Aquastar A8Rxxx equalizer line covers installed that extend >2" from the pool wall. APSP federal standards require no protrusion >2" from pool wall. Covers shall be replaced/repaired to meet rule requirement. If changed, a new PDSC form shall be submitted for approval. Challenger 2 hp pump with max flow of 139 gpm. Wall covers shall be capable of handling at least 70 gpm. Pool already closed to the public. Permit will not be issued until repaired. Intent to Suspend issued for 1/2" offset for equalizer line cover, gate self-closing, self-latching and double gate secured in place, and lighting documentation. Pool not approved for salt as primary chlorination. Alan Gardner present for the inspection. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Some reagents expired in test kit. Replace reagents as needed.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No >1/2" between wall and equalizer line covers on the wall. Eliminate offsets and protrusions >1/2". Intent to Suspend issued.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Vacuum cap not in place at start of inspection. Replaced during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate off of private patio not self-closing, self-latching. Intent to Suspend issued. Double gate not locked in place due to maintenance. Provide lock to ensure self-closing, self-latching. Intent to Suspend issued. One picket at private patio bent to >4". Barrier wall less than 45" from top of fencing/gates. Maintain 45" between horizontals. Provides a foothold. Pool built pre-2010. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Swing stage on deck due to repair work being done. Maintain 6 ft. clearance around the swimming pool. Damage to pool deck nearest skimmer by gate entry. Continue to monitor and repair as needed.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Perimeter lights not verified at time of inspection. On photocell. Provide photograph documentation to show operable for night swimming approval. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room left unlocked. Ensure locked when not in use.