5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records maintained. Record chlorine, pH and main drain checks daily. Cyanuric acid and alkalinity weekly.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder rung 6 1/2" from wall to rung.
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Vacuum line without fitting. Corrected during inspection.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy rope tangled and body hook not accessible on pool deck. Rope un-tangled and body hook moved to hooks so easily accessible.
.2530(a) Lifesaving equipment should be conveniently located. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Barrier wall less than 45" from top of fencing/gates. Maintain 45" between horizontals. Provides a foothold. Pool built pre-2010.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
Back gate entry from private residence was locked shut. Verified during inspection to self-close, self-latch. Gate shall remain self-closing, self-latching. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck furniture <6 ft. to pool edge. Provide clear walking space on deck. Walking space still available and not blocked in any location.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Minor deck damage at step entry. Continue to monitor. If offset is >1/2", must repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. |