Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameYMCA STRATFORD RICHARDSON
Address1946 WEST BV
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/6/2021
Final Score @ Grade
36
General CommentsEmergency phone ring back must be audible or to desk monitored 24/7, if not routed to phone, staff must be able to identify emergency call location by 12/13. Main drain inspection documentation must be provided at next visit. Failure to provide these items will result in immediate suspension of permit. Contact Marie Daley at 704-507-6806 when in compliance. 30 Day Intent to Suspend (ITS) items include: records (daily, available, TA checks, maintenance), CPO certification, offsets within 5' of pool (basketball goal), depth markers and automatic feeders shut off with pump. Changed to "W" ITS status Inspection with Jemarion Young No signature due to COVID Note: Cone over water feature bottom starting to crack and not completely secure. Keep in good repair. Not currently a hazard, but may warrant permit action in future.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing total alkalinity at time of inspection. Multiple days of records missing and not available. No CPO at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. *30 Day Intent to Suspend (ITS) item
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Main drains require annual check per manufacturer. Last check documented was 12/16/2020. Must provide written documentation of main drain check by expiration. Will verify this item at return visit. Failure to provide written documentation of drain cover in good repair and inspected (annually) will result in permit action. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. **Permit item.**
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth marker on wall missing "IN" for complete depth of pool at this area. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. *30 Day ITS item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection. Keep accessible. ..2530(a) Lifesaving equipment should be conveniently located. Lifeguard untangled and corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Basketball goal (not in use) within 5' of pool deck. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. *30 Day ITS item
22 6 Premises: emergency telephone provided No No No Emergency phone dialing out, but not audibly ringing back to pool. Phone must ring back in case of emergency. Allowed 7 days for correction. Contact Marie Daley at 704-507-6806 when in compliance. Failure to correct will result in permit action. .2530(f) Emergency phone shall remain operable. **Permit item**
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Unable to verify feeder at time of inspection. .2535(6) Automatic chlorine and acid feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. *30 Day ITS item
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restroom over 110 degrees F at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F.