Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHOLIDAY INN EXPRESS HOTEL
Address805 W ARROWOOD RD
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/4/2016
Final Score @ Grade
26
General Comments#12 Missing 1 inlet fitting. ** Install. GC #30 Fill spout ~8.5" from ladder. ** Maximum distance allowed is 6". Notes: (1) Door from lobby to pool has "Pool Closed" sign; however, taped note on door states pool water heater broken, pool water 80F, swim if you want, etc. Conducted inspection. Note removed (from door) & CPO advised to keep pool closed or allow it to be open with water quality standards maintained, etc. (2) Correct dialing instructions "lift handset phone automatically dials 911" posted inside emergency phone box; however, sign above states "dial 911". ** Dial 911 on sign above blacked out. (3) Remove grill from restroom. CPO reports grill for staff cookouts & is just being stored in restroom. IMMEDIATE SUSPENSION ISSUED FOR #2. Pool cannot be re-opened without written approval from the MCHD. EHS training staff for pool authorizations.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine @ .4ppm. ** Maintain at least 1ppm. Immediate Suspension.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor chipped in several areas by steps. ** Re-paint. Some soil/ scum on pool wall tiles. ** Clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer missing weir. ** Install.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing rubber tread on one step. ** Install. Handrail getting loose. ** Secure.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope wrapped (in & out) of ring buoy & beckets (straps) pushed together on ring buoy. Throw rope 22' long due to knots. ** Corrected during inspection (except beckets) while EHS on-site. CPO has new ring buoy in storage.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Forced air vents in chemical & equipment room not working (& no natural cross draft ventilation). ** Resolve. (Some) chemicals stored in equipment room. ** Store in chemical room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water 119F @ lavatory & shower. ** Maximum allowed is 110F.