8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 1 out of 2 total weirs missing. . 2518(k) Replace missing weirs.
*permit item |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter too discolored to verify reading or if operable.
.2518(g) A flow meter, reading in gallons per minute shall be installed per manufacturer instructions.
Keep flow meter operational.
*permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Bags of chemicals on floor in pump room. Pump room floor wet. Ladder and items around equipment, no 3’ clearance.
.2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(d) Pump room floor shall be kept dry and free of standing water. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Water in restrooms over 110 F. .2526(i) Water in restrooms shall not exceed 110 F. |