Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Observed depth markers on wall below pool water level.
Provide depth markers on walls every 25' on perimeter of the pool.
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed door alarms not functioning.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Observed automatic acid feeder not indicating no flow when pool circulation stops.
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. |