16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Column with foot hold greater than 3” creating horizontal by fence less than 45" in height by clubhouse/fitness room area. Pool built '04. No permit action.
.2528(b) Horizontals shall not be located less than 45" in height.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Posted callback number incorrect. Operator corrected by posting corrected callback number on signage. No permit action. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(c) Valves and controls shall be accessible to the pool operator at all times.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Maintain 3 ft. clear walking space in pump room. Observed pump room used to store non-pool related items. Bulk chlorine and acid feed containers in pump room. |