Premises Information

Return to Inspections
NameCOTTONWOOD RESERVE
Address2325 COURTNEY OAKS RD
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/23/2025
Final Score @ Grade
20
General CommentsConducted inspection with CPO Maurice. Intent to suspend issued for gate/fence issues and underwater light. Contact EHS Devon when corrected 7049981122. Items must be corrected within 30 days or permit may be suspended. DRAIN COVERS EXPIRE 4/20/2026 No night swimming Const. Date: 3/1/2004 Rope Length: 50’ No listed permit conditions

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool water pH less than 6.8. Operator corrected. No permit action.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope tangled and inaccessible. Operator untangled and corrected. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No All gates have an 3” foothold magnetic latch on the outside. Install a slanted cover above latch on each gate or raise mechanism to 48” to correct. Opening to the left of back gate more than 4”. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Openings in the barrier shall not allow passage of a four-inch-diameter sphere and shall provide no external handholds or footholds. Solid barriers that do not have openings shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. Intent to suspend item. Column with foot hold greater than 3” creating horizontal by fence less than 45" in height by clubhouse/fitness room area. Pool built '04. .2528(b) Horizontals shall not be located less than 45" in height. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. Underwater light on the right of the pool coming out of socket. Intent to suspend item.