15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope less tha 50’ and detached. Operator replaced with 50’ rope. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching. Door leading directly onto pool deck from fitness center not latching closed and not alarmed. Operator corrected to make alarmed during inspection
Column with foot hold greater creating horizontal on fence less than 45" in height by clubhouse/fitness room area. Landscaping shortening height of fence in someareas. Pool built '04. .2528(b) Horizontals shall not be located less than 45" in height. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Some loose deck bricks, some offset of bricks and gaps between bricks right at 1/2”. No permit action at this time however issue must be resolved prior to 2024 permitting. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Flow meter not operational during inspection - corrected by operator |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(l) Provide toilet paper and dispensers in restrooms. Missing toilet paper at some fixtures in womens restrooms. Missing paper towels in both restrooms. |