NameCOTTONWOOD RESERVE
Address2325 COURTNEY OAKS RD
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/19/2023
Final Score @ Grade
20
General CommentsInspection conducted with operator, Maurice Grier. Night swimming is not approved. Note: loose and/or offset brick tiles must be corrected prior to issuance of 2024 permit

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope less tha 50’ and detached. Operator replaced with 50’ rope.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Door leading directly onto pool deck from fitness center not latching closed and not alarmed. Operator corrected to make alarmed during inspection Column with foot hold greater creating horizontal on fence less than 45" in height by clubhouse/fitness room area. Landscaping shortening height of fence in someareas. Pool built '04. .2528(b) Horizontals shall not be located less than 45" in height. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Some loose deck bricks, some offset of bricks and gaps between bricks right at 1/2”. No permit action at this time however issue must be resolved prior to 2024 permitting.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter not operational during inspection - corrected by operator
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(l) Provide toilet paper and dispensers in restrooms. Missing toilet paper at some fixtures in womens restrooms. Missing paper towels in both restrooms.