NameCOTTONWOOD RESERVE
Address2325 COURTNEY OAKS RD
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/31/2021
Final Score @ Grade
38
General Comments30 Day Intent to Suspend (ITS) issued for records, depth marker (FT), gates, flow meter, pool floor and weirs. Will also verify chemical storage does not have imminent hazard risk. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Changed to "W" status. Inspection with Wade Long (presented CPO card, main CPO not working daily on day of inspection) No signature due to COVID No Night Swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator corrected to 7.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing some days in previous month and no weekly total alkalinity and cyanuric acid recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Recorded and corrected. *Permit item
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Sand, debris and black specs on pool floor at time of inspection. .2537(14) Keep pool surface and pool floor free of debris. Operator stated vacuum broke and working on cleaning. *Permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets observed with leaves and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected. Some weirs observed missing. .2518(k) Replace missing weirs. *Permit item
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 4 1/2 FT depth marker missing "FT". .2523(c) Depth markers shall include the word "feet" or symbol "ft". *Permit item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection. .2530(a) Lifesaving equipment should be conveniently located and accessible. Operator untangled and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Side of building creating horizontal by fence less than 45" in height by clubhouse. Landscaping shortening height of fence in some areas. Pool built '04. .2528(b) Horizontals shall not be located less than 45" in height. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Gate not opening or closing in back. .2537(b) All gates and doors shall be self-closing, self-latching. *Permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational at time of visit. .2518(g) Keep flow meter operational. *Permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in pump roomwithin 3' clearance of piping. Chemical storage room had shelves break and all chemicals are piled on top of each other. This incident happened on day of inspection and operator is working to clean/organize. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.