Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOTTONWOOD RESERVE
Address2325 COURTNEY OAKS RD
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/24/2021
Final Score @ Grade
14
General CommentsSkimmer equalizers have been corrected to be plugged in correct holes. Water quality in compliance and chlorinator working at time of inspection. Emergency phone signage has been corrected with "Dial 911" Issued permit. No Night Swimming. Inspection with Maurice Grier No signature due to COVID Pool not heated. Management working with landscaping to address fencing and pine straw around fence, shortening to less than 48" in height.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing last few days and no weekly total alkalinity and cyanuric acid recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Recorded and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Side of building creating horizontal by fence less than 45" in height by clubhouse. Gap on gate greater than 4". Landscaping shortening height of fence. Closer installed creating horizontal less than 45". Pool built '04. Operator removed closer and moved to 45". Corrected. .2528(b) Horizontals shall not be located less than 45" in height..2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Some landscaping cleared. Operator pulled rods together to eliminate gap. Corrected. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Gate not closing in back. .2537(b) All gates and doors shall be self-closing, self-latching. Operator corrected to self-close, self-latch. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Liquid chemicals stored above dry. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in men's restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink. Operator provided soap. Corrected.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Backflow preventer at restroom off. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Operator replaced and corrected.