5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Total alkalinity, thiosulfate reagents expired. DPD-2 reagent almost gone. Provide new test kit chemicals for test kit. Intent to Suspend issued. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pool barrier at 44" at some pillars on wall. .2528(b) Horizontals shall not be located less than 45" in height. Barrier wall outside of pool fence located directly next to fence. <45" between horizontals from wall to fence and openings >4" above. Maintain 4" or less between openings. Pool built pre-2010. Observed mt gate at the back entry by the restrooms not permanently locked. Recommended to be locked when not used. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some damage to grout around skimmer closest to pump room and gate entry. Damage to deck tile also. No offset >1/2". Monitor and repair. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
New lighting installed around the pool perimeter. Could not verify operable. Pool is approved for night swimming. Provide photograph of lighting operational at night.
One pool light not operable. Replace/repair light. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone number posted at pool phone goes to the emergency phone; however, 911 has front office number in system when transferred from Kings III. 911 called back to property and had concierge phone number. All three phone numbers now posted at pool phone. Given two weeks to correct. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet. Equipment does not appear to be leaking. Operator indicated coming from sprinkler system. |