Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFIFTH AND POPLAR RCOA
Address300 W 5TH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/30/2023
Final Score @ Grade
18
General Comments15 - Minor fraying on ring buoy rope. Monitor. Rope still intact and secure at time of inspection. Replace when brittles. Note: Phone breaking in and out when speaking with 911. 911 still audible. Monitor and get service on phone if issue worsens. Intent to Suspend issued for: .2524 - repair lighting so that all pool and perimeter lights operable for night swimming approval .2528 - repair window limiters to open at 4" or less Jon Fife present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Debris and leaves on pool floor. Main drains with some debris. Still visible. Keep pool floor clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Debris/leaves under skimmer baskets on two skimmers. Keep free of debris to ensure proper filtration of water through system.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Two windows (next to wall at treadmills and at far left of weight room) with window limiters >4"/not operable. Repair to limit windows at 4" or less. Intent to Suspend issued. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pool barrier at 44" at some pillars on wall. .2528(b) Horizontals shall not be located less than 45" in height. Barrier wall outside of pool fence located directly next to fence. <45" between horizontals from wall to fence and openings >4" above. Maintain 4" or less between openings. Pool built pre-2010. Observed mt gate at the back entry by the restrooms not permanently locked. Recommended to be locked when not used.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No .2524 For Night Swimming - provide sufficient lighting so that all parts of the pool and required deck area are visible and main drains are clearly visible. One pool light not operational. Two lights to right of double doors (first and third light) not operational. Pool permitted for night swimming. Lights must be operable in pool and around perimeter for night swimming. Limit hours to dawn to dusk until repaired. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet due to leak at check valve. Repair leak or plumb catch drain to backwash pit to keep pump room floor dry. Hose stored on floor next to pump in pump room. Maintain 3 ft. clearance around equipment in all locations.