Premises Information

Return to Inspections
NameFIFTH AND POPLAR RCOA
Address300 W 5TH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/18/2021
Final Score @ Grade
34
General Comments15 - Ring buoy grab rope brittle and rope in need of replacement. Replace with USCG approved ring buoy and 38 ft. rope within 30 days. Will verify on return visit. Intent to Suspend issued for lighting verification and providing spare pump basket. A return visit will be made in 30 days to verify ring buoy and ITS items. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Pool test kit tube with black on bottom. Tube used for CYA. Replace test kit tubes.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with debris. Keep free and clean to ensure pump/circulation is adequate.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pool barrier at 44" at some pillars on wall. .2528(b) Horizontals shall not be located less than 45" in height. Barrier wall outside of pool fence located directly next to fence. <45" between horizontals from wall to fence and openings >4" above. Maintain 4" or less between openings. Barrier not secure at main entry near fountain. Piece of barrier broken. Repair barrier. Pool built pre-2010.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some damage to grout and tile around one skimmer. Some damage to tiling around step handrail. Offsets not >1/2". Continue to monitor and repair if worsens.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Could not verify lights operable. Pool operator not present. Pool approved for night swimming. All perimeter lights and interior lights shall be operable. Intent to suspend issued.
22 6 Premises: emergency telephone provided No No No Address and phone number faded on emergency pool phone signage. Written in with sharpie during the inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Filter leaking. Repair leak. No spare pump basket for pool pump. Provide spare pump basket. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet in pump room. Keep dry. Ventilation in door with no forced draw or cross ventilation. Provide continuous forced ventilation or cross ventilation.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water in restrooms >110 F. Maintain at 110 F or below.