5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed several days missing daily records of pH, chlorine, drain cover inspections, etc. in December and November of 2019.
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed expired chemicals inside test kit. New test kit is not on site. PIC unable to provide test strips. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed heavy debris in all skimmers. One skimmer not pulling. Corrected during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pool barrier at 44" at some pillars on wall.
.2528(b) Horizontals shall not be located less than 45" in height. Barrier wall outside of pool fence located directly next to fence. <45" between horizontals from wall to fence and openings >4" above. Maintain 4" or less between openings.
Pool built pre-2010. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(h) Provide a NSF listed pump per manufacturer. Observed small leak at line into pump. Continue to monitor. Leak does not appear to affect circulation of pool. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed neither forced ventilation nor cross ventilation inside pump room. Only one vent in door. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(i) Water in restrooms shall not exceed 110 F. Observed both men's and women's restrooms handsink temperatures at 114F and 115F.
.2526(m) Keep restrooms and fixtures clean and in good repair. One sink slow draining in women's. |