5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
CYA recorded at 100 ppm for repeated days. Maximum cyanuric acid level requires less than 100 ppm. Lower CYA to below 100 ppm. Intent to Suspend issued.
CPO must visit property daily. No CPO employed at facility. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fasteners (horizontals) from pillars to fence provide footholds at less than 45" apart. <45" from pillar to top of fence at walls. Ash Tray provides footholds measuring less than 45". Fence built prior to 2010. Maintain 45" or greater between horizontals. Could not verify windows. All windows opening on to pool deck shall open 4" or less. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Tumbled pavers used for coping. Some openings >1/2". Fill holes to eliminate openings >1/2". Intent to Suspend issued. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not dialing out to 911. Corrected during inspection. Will re-verify phone on return visit. Incorrect dialing instructions at phone. Corrected during inspection. Incorrect phone number posted at phone. Corrected during inspection. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Staff onsite could not verify chlorinator. Automated chlorinator must detect flow and shut off chemical feeding when no flow. Operator must demonstrate. Intent to Suspend issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Keep operational. Intent to Suspend issued. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Water in restrooms >110 F. Maintain at 110 F or below. |