Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON GARDEN INN
Address9315 STATESVILLE RD
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/10/2023
Final Score @ Grade
30
General CommentsInspection conducted with inspector Jordan Johnson and maintenance staff Tyrone Williams. Not able to verify lighting for night swimming permit. Will return to verify lights work. Pool is heated. Heater was off at the time of inspection. No free chlorine in the pool. Automatic chlorinator was off. Facility has issues with GFCI receptacle tripping. Recommend replacing. Test kit reagents recently expired or will be expiring soon. Recommend getting a new test kit. Intent to suspend issued 8) 16) 17)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Corrected to 3ppm.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir broken. .2518(k) Provide functional weirs. - Intent to suspend item. Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrail missing escutcheon plate. .2521 Install handrails per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope for one of the ring buoys snapped and tied back together. .2530(a) Provide USCG approved ring buoy with 18 foot throw rope. Rope must be continuous. - Ring buoy with damaged throw rope removed by maintenance. Still have one ring buoy and throw rope on pool deck that meet requirements.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door from lobby to pool deck does not latch, is not alarmed. This is a repeat issue. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Intent to suspend item. Gate stuck standing open. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. - Intent to suspend item. Pre-2010 fence less than 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. Portion of pool deck on indoor portion of pool chipping. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan in chemical storage room not working. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Fan in pump room not working. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled or labels heavily faded. .2518(d) Piping and valves shall be labeled with color codes or labels.