Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON GARDEN INN
Address9315 STATESVILLE RD
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/1/2021
Final Score @ Grade
38
General CommentsInspection conducted with Engineer Mike Simpson. Due to COVID-19 precautions, inspection not signed by the engineer. Verified outdoor lights were in good working order. Pool still permitted for night swimming. Pool not currently heated. Heater turned off and pool water bypasses the heater. Intent to suspend issued 5) 17) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Corrected to 3 ppm.
3 6 Water quality: pool water pH No No No pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid test showed no stabilizer in the pool. .2535(4) When chlorine is used as the disinfectant it must be stabilized with cyanuric acid not to exceed 100 ppm. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrail missing escutcheon plate. .2521 Install handrails per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No One ring buoy with throw rope that was too long. .2530(a) Provide USCG approved ring buoy with 18 foot throw rope. Corrected by operator.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door from lobby to pool deck does not latch, is not alarmed. This is a repeat issue. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Alarm turned on by hotel staff.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some chairs on outdoor pool deck too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Spare pump basket not observed. .2518(e) Provide a spare basket for pump. - Intent to suspend item. Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan in chemical storage room not working. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Fan in pump room not working. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.