2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Corrected to 3 ppm. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Cyanuric acid test showed no stabilizer in the pool. .2535(4) When chlorine is used as the disinfectant it must be stabilized with cyanuric acid not to exceed 100 ppm. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Handrail missing escutcheon plate. .2521 Install handrails per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
One ring buoy with throw rope that was too long. .2530(a) Provide USCG approved ring buoy with 18 foot throw rope. Corrected by operator. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door from lobby to pool deck does not latch, is not alarmed. This is a repeat issue. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Alarm turned on by hotel staff. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs on outdoor pool deck too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Spare pump basket not observed. .2518(e) Provide a spare basket for pump. - Intent to suspend item.
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan in chemical storage room not working. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Fan in pump room not working. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |