NameHILTON GARDEN INN
Address9315 STATESVILLE RD
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/23/2019
Final Score @ Grade
30
General CommentsIntent to suspend issued. 5) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets full. Corrected by operator.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy damaged. Corrected by operator.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence less than 48" high in places. Maintain fence at least 48" high with no gaps > 4" under the fence.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and table too close to the pool. Corrected by operator.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair or replace. - Intent to Suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not functioning in chemical storage room. Provide either forced air or cross ventilation.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water > 110F. Maintain at 110F or less.