Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON GARDEN INN
Address9315 STATESVILLE RD
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/28/2016
Final Score @ Grade
30
General CommentsPermits posted are expired. Go to Meckpools.charmeck.org to print current permits and post in pool/spa area.Pump information on approved PDSC form does not match what is installed. Fill out new PDSC form and submit to our office. Pump installed was Hayward RS1500.Immediate suspension issued.2)Contact Will Harrison (704-507-6824) for reinspection when issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. Maintain at least 1 ppm free chlorine. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Improper reccord keeping. No dates, unable to tell pool records from spa records, missing needed information. Check daily Cl, pH, main drains and temperature. Check at least weekly TA and CYA. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope length shall be 18 feet long. One of the throw ropes too short. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to lobby not self-latching. Make all gates and doors self-closing and self-laching. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair or replace.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in pump room at pool chlorine feeder. Fix feeder.Vent off in chemical storage room. Chemical storage room shall have continuous ventilation. Corrected by operator.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Pipes missing labels or incorrectly labeled. Label all pipes. Pool has vacuum line, none of the pipes in the pump room was labeled as the vacuum line.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Post signage in outside pool area directing bathers to shower before entering the pool.