Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameUNIVERSITY WALK APARTMENTS
Address1205 UNIVERSITY WALK CIRCLE
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/9/2023
Final Score @ Grade
30
General CommentsLeasing office being renovated at time of inspection. Doors to pool deck were kept unlocked. All doors must remain self-closing, self-latching when the pool is open to the public. Ring buoy grab rope degrading. Bottom of ring buoy rope starting to fray. Given one week, until 11/16, to replace ring buoy with USCG approved buoy and 50 ft. rope. Intent to Suspend issued for the following: .2523/.2537 - replace 3 1/2 ft. sticker depth markers to measure 4" in height where needed; provide 4 ft. depth marker on pool wall and deck at far right side of pool between 5 ft. and 3 1/2 ft. .2528 - repair double doors to self-close, self-latch .2522/.2537 - provide plug for fill line. Shall not offset greater than 1/2" Marion Lloyd present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One damaged skimmer basket. Replace basket.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Sticker 3 1/2 ft. depth markers on pool wall/deck less than 4" in height. Replace with depth marker measuring 4" or greater. Intent to Suspend issued. >25 ft. between 5 ft. and 3 1/2 ft. depth marker at far right side of pool. Provide 4 ft. on pool wall and deck in 4" lettering between 5 ft. and 3 1/2 ft. Intent to Suspend issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Double doors into leasing office not self-closing, self-latching. Need adjusted. Repair to self-close, self-latch. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Fill line missing plug on pool deck next to ladder handrail. Provide plug that does not exceed 1/2" offset. Intent to Suspend issued. Some deck damage next to handrail by fill line. Does not warrant repair at time of inspection. Continue to monitor and repair if worsens.
22 6 Premises: emergency telephone provided No No No Incorrect phone number posted at pool phone. Corrected during the inspection.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorinator without flow meter. If ever replaced, install per NSF requirement. Original construction.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Most lights burnt out in pump room. Provide lighting.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Provide air gap.