8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One damaged skimmer basket. Replace basket. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Sticker 3 1/2 ft. depth markers on pool wall/deck less than 4" in height. Replace with depth marker measuring 4" or greater. Intent to Suspend issued.
>25 ft. between 5 ft. and 3 1/2 ft. depth marker at far right side of pool. Provide 4 ft. on pool wall and deck in 4" lettering between 5 ft. and 3 1/2 ft. Intent to Suspend issued. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Double doors into leasing office not self-closing, self-latching. Need adjusted. Repair to self-close, self-latch. Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Fill line missing plug on pool deck next to ladder handrail. Provide plug that does not exceed 1/2" offset. Intent to Suspend issued.
Some deck damage next to handrail by fill line. Does not warrant repair at time of inspection. Continue to monitor and repair if worsens. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Incorrect phone number posted at pool phone. Corrected during the inspection. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorinator without flow meter. If ever replaced, install per NSF requirement. Original construction. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Most lights burnt out in pump room. Provide lighting. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |