Select your filters and click the Search button to search for data, or click Clear to clear all filters
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
Premises Information
Return to Inspections
Name
UNIVERSITY WALK APARTMENTS
Address
1205 UNIVERSITY WALK CIRCLE
City/State/ZIP
CHARLOTTE
NC
28213
Premise Type
53 - Year-Round Swimming Pool
County
Mecklenburg
Inspection Date
10/5/2021
Final Score @ Grade
2
General Comments
Inspection conducted with Marion Lloyd. Due to COVID-19 precautions, inspection was not signed by the operator. Also conducted in-field plan review for two newly installed Pentair Whsiperflo XF-VS pumps. Electrical permit E4009701 finaled on 7/28/2021, permit E3923275 finaled on 3/30/3021. Permit restriction is that FloVis flow meter read between 220 GPM and 230 GPM, as minimum turnover is 221 GPM and return line is rated for 230 GPM. When I arrived flow meter read 230 GPM with both pumps operating at 3100 GPM. Operator adjusted speed to 2850 RPM for both pumps to achieve 220 GPM. This was not after a fresh backwash. Some air bubbles in pump basket closest to the inlet side. Could be due to it being installed too close to multiple elbows, or there may be an air leak. Recommend having installer verify that there are no issues with the pump or piping. Permit sticker issued Permit will be posted online at Meckpools.Charmeck.org in 3-5 business days. Please print a copy for your records.
Violations
CDI=Corrected During Inspection
R=Repeat Violation
VR=Verification Required
Violation Item
Demerits
Violation Description
CDI
R
VR
Comments
26
2
Equipment room: valves and pipes identified by color codes or labels
No
No
No
Some piping not labeled in the pump room. .2518(d) Piping and valves shall be labeled with color codes or labels.