5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no temperature recordings for pool. Intent to suspend permit issued. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed 2 wooden boards damaged at retention wall behind lifeguard room causing the barrier to be less than 48 inches tall. Pool was constructed prior to 2010 therefore no permit action required. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed 2 damaged wooden boards at retention wall behind lifeguard room causing a gap larger than 4x4 inches. Pool constructed prior to 2010 therefore no permit action required |