NameRESIDENCE INN BY MARRIOTT
Address6030 PIEDMONT ROW DR S
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/28/2023
Final Score @ Grade
28
General CommentsInspection conducted with Hotel Manager John Sullivan. 30 day intent to suspend is issued for non compliant no diving tiles. Return visit will be made in 30 days. If tiles remain non compliant, permit may be suspended. Chlorine found to be at least 10ppm. EHS recommends reducing chlorine level. Inspection conducted by Devon Moeller under supervision of Hope McIntosh.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
4 6 Water quality: water temperature of heated pool No No No .2535(12) Maintain pool temperature at 90 F or below. Temperature measured at 91 degrees. Water heater temperature reduced to correct.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Missing few daily records. Ensure records are kept daily. Discussed with operator. No permit action.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Multiple no diving tiles worn/no longer clearly visible and not in good repair. Repair or replace no diving tiles. *Intent to suspend to item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Ladder loose.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 19ft. Operator corrected to 24 ft.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Some pool furniture less than 5ft from edge of pool. Operator corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals store in pump room. Separate chemical room present but not used. Pool built 2001.