Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRESIDENCE INN BY MARRIOTT
Address6030 PIEDMONT ROW DR S
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/6/2020
Final Score @ Grade
14
General CommentsVisit to pool to lift Intent to Suspend (ITS) for record keeping, CPO, skimmer baskets, depth markers, inlet fittings, coping and deck offsets greater than 1/2". At time of visit records missing total alkalinity. All other items in compliance. Operator recorded alkalinity for the week and corrected. ITS lifted and conducted inspection. Placed in "A" Open for Business.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly total alkalinity recordings on day of inspection. All other records in compliance. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Educated operator on how to measure alkalinity. Operator measured and recorded. Corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone number posted did not match emergency operator callback number at time of inspection (704-554-1355). Sinage directs caller to "Dial 911", but phone auomatically dials 911 when lifted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator made new signage and posted. Corrected. *Note: Phone calls back to front desk, not pool phone line, with alert at front desk phone. Front desk must be monitored 24/7 if phone does not directly dial back to emergency phone to ensure routing calls correctly in emergency.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room and feeder installed by piping. Water on floor in pump room. Pool built '01. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(d) Pump room floor shall be kept dry and free of standing water.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water over 110 degrees F in restroom. .2526(i) Water in restrooms shall not exceed 110 F.