5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing weekly total alkalinity recordings on day of inspection. All other records in compliance.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Educated operator on how to measure alkalinity. Operator measured and recorded. Corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone number posted did not match emergency operator callback number at time of inspection (704-554-1355). Sinage directs caller to "Dial 911", but phone auomatically dials 911 when lifted.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator made new signage and posted. Corrected.
*Note: Phone calls back to front desk, not pool phone line, with alert at front desk phone. Front desk must be monitored 24/7 if phone does not directly dial back to emergency phone to ensure routing calls correctly in emergency. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room and feeder installed by piping. Water on floor in pump room. Pool built '01.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(d) Pump room floor shall be kept dry and free of standing water. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water over 110 degrees F in restroom.
.2526(i) Water in restrooms shall not exceed 110 F. |