NameRESIDENCE INN BY MARRIOTT
Address6030 PIEDMONT ROW DR S
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/2/2015
Final Score @ Grade
30
General Comments# 25 Equipment room floor wet due to pipe leak (See #24) and will be corrected. GC # 28 No "Shower Before Entering Pool" sign. ** Obtain & post. Notes: (1) Water level at least 1' below skimmers (by accident); however, pool still open. ** Maintain proper water level. (2) Caulk around equalizer line cover that will not sit flush with pool wall. Pool permit suspended/ IMMEDIATE SUSPENSION ISSUED FOR #2, #15, #22. Pool cannot be re-opened without written approval from the Mecklenburg County Health Department.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Bromine @ .4ppm. ** Maintain at least 2ppm. Immediate Suspension. (IS)
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Straps on ring buoy have been relocated (pushed together) & twisted so the rope that is part of the ring buoy is no longer properly positioned. ** Correct. Replace ring buoy if necessary. (IS)
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door leading from hallway into pool enclosure will not self-close completely. ** Correct.
22 6 Premises: emergency telephone provided No No No Phone number posted @ emergency phone (704-554-7001) does not match the phone number that 911 has (which is 704-554-1355). ** Post correct phone number. (IS)
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Bad leak @ connection of outlet pipe & pump. ** Resolve. Flow meter float stuck. ** Keep operational.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash pipe extends down into sump. ** Provide complete air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water at least 123F at lavatories in restrooms. ** Maximum allowed is 110F.