Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBALLANTYNE HOTEL AND LODGE, THE POOL INDOOR
Address10000 BALLANTYNE COMMONS PKY
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/25/2026
Final Score @ Grade
12
General CommentsInspection with Joe Diesare. Pool pumps may be changed for variable speed. An in-field plan review application is required for approval for pump changes. Electrical permits must also be pulled. Motor has been removed from lion fountain pump.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly total alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked alkalinity, recorded value. Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Both skimmer weirs upside down. .2518 Repair weirs to meet NSF approval/manufacturer instructions. Operator turned around, installed correctly and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet around equipment. Ensure no leaks in pump room and dry floor. Bags of dry items on floor in chemical storage. .2533(d) Pump room floor shall be kept dry and free of standing water. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water in shower over 110 degrees F. .2526(i) Water in restrooms shall not exceed 110 F.