Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBALLANTYNE HOTEL AND LODGE, THE POOL INDOOR
Address10000 BALLANTYNE COMMONS PKY
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/26/2024
Final Score @ Grade
30
General Comments16 - Tables located on outside of pool fence that provide foothold. Move tables to eliminate footholds to get over barrier. Note: Feed for treated water is tied into line before the heater. Recommend moving the water line to after the heater so not to put highly chlorinated water through the heater. Intent to Suspend issued for .2524 - repair light for night swimming approval.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 6.9. Corrected to 7.2 during the inspection. Maintain at 7.2 to 7.8.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Both skimmer weirs upside down. Repair weirs to meet NSF approval.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One step handrail loose, closest to double door entry to pool. Tighten step handrail.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No One of two pool lights burnt out. Pool is approved for night swimming. Replace light. Intent to Suspend issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Small leak at chlorinator flow meter. Repair leak.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not installed per mfg. instructions. No permit restriction on the pump. If replaced, ensure installed per mfg. instructions. Small leak at filter lid. Repair leak.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak at filter and at chlorinator flow meter. Keep pump room floor dry.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labeling starting to wear off on piping. Clearly identify all pipe with color codes or labels.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Both soap dispensers in women's restroom not operable. No soap coming out when activated. Toilet seat in women's restroom loose. Provide soap in restrooms and keep fixtures in good repair.